Double check valve

In plumbing

Two check valves in one body, one after the other, so water is still held back if one of them fails to seal. It is common on appliances and outside taps where the backflow risk is moderate, and it is no substitute for an air gap where the water could be seriously contaminated.

Using Double check valve in a plumbing system

Updated

A distinction worth remembering

Backflow can result from a pressure drop upstream or higher pressure downstream. An arrangement suitable for one fluid category may be unsuitable for another. Water Regs UK explains the differences between backflow devices and air-gap arrangements; the water supplier can advise on the applicable case.

Questions to take further

Is a double check valve suitable for every backflow risk?
No. Protection must match the fluid category and the pressure conditions. Higher-risk uses can need an appropriate air gap or other suitable arrangement; do not choose a device merely because it fits the pipe.

Sources

Where Double check valve fits in the learning path

The Cold Water Basics section covers these topics:

  • The Incoming Water Supply
  • Cold Water Storage and Backflow

See every plumbing topic

Read, practise, return

  1. 1. Read it in context

  2. 2. Try recalling, then explore practice

    Use the memory prompt below to connect the vocabulary.

  3. 3. Return to the meaning

    After reading or practising, explain the idea in your own words, then check what you remembered.

    Revisit the Double check valve definition

Recall a related term

Which term fits this definition? Say it to yourself, then reveal it. This is a memory prompt, with no score or saved result.

A valve that lets water pass one way and closes if it tries to flow back. A single check valve gives protection where the backflow risk is low; where the risk is higher, a double check valve or an air gap is used instead, matched to the fluid category of the water involved.

Open a meaning to compare its role with Double check valve, or follow its full entry.

Check valve — Non-return valve

A valve that lets water pass one way and closes if it tries to flow back. A single check valve gives protection where the backflow risk is low; where the risk is higher, a double check valve or an air gap is used instead, matched to the fluid category of the water involved.

Read the Check valve entry
Air gap

A physical gap between the outlet of a pipe or tap and the highest level the water below it could reach, so that water cannot be drawn back into the supply. Because there is nothing in it that can fail, an air gap is the protection used against the highest-risk water, such as a category 5 source. A tap whose spout sits well above the spill-over level of a basin is a familiar example.

Read the Air gap entry
Backflow

Water flowing the opposite way to the one intended, for example from a hose left in a bucket, a cistern or an appliance back into the pipe that supplies drinking water. It can happen when the supply pressure drops, or when the system downstream is at a higher pressure. The water fittings rules in each UK nation require protection against it that matches the risk, judged by fluid category.

Read the Backflow entry

Before you start: some plumbing work is regulated or notifiable

Some water fittings work needs notice to, and consent from, the water supplier before it starts. Check the rules where you live.

Gas work is for competent workers covered by a Gas Safe registered business in Great Britain. Northern Ireland has separate gas regulations. Do not work on gas pipes or appliances yourself.

In England, installing an unvented hot-water system over 15 litres is notifiable building work: use a competent installer registered with a competent-person scheme, or tell building control before work starts. Leave this work to a suitably skilled person.

Wales, Scotland and Northern Ireland have their own water and building rules; check which apply before work starts. Electrical connections belong with an electrician.

This guide does not qualify you or make you competent, approved or registered for plumbing, gas or unvented work.

A definition is a start. Using it in a real question is where it sticks.

By starting, you agree to our Terms and Privacy notice.

Double check valve Meaning in UK Plumbing | TradeTraining