Indirect cylinder

In plumbing

A hot-water cylinder heated by water from a boiler or heat pump flowing through a coil inside it. The heating water and the water drawn at the taps never mix. A direct cylinder, by contrast, heats its own stored water, for example with an immersion heater.

Using Indirect cylinder in a plumbing system

Updated

A distinction worth remembering

A cylinder fed from a cistern behaves differently from one sealed and fed from the main. Pressure, the parts on the inlet and the safety devices all follow from that one fact. Learn to tell the two apart and to see which faults belong to a competent unvented installer.

Questions to take further

Is a dripping discharge pipe on an unvented cylinder a minor nuisance?
No. It shows a relief valve is opening, so something in the system is not working as designed. The discharge route stays open and the fault goes to a competent installer.

Sources

Where Indirect cylinder fits in the learning path

The Hot Water Systems section covers these topics:

  • Hot Water Cylinders
  • Combis and Instant Hot Water
  • Hot Water Temperature Control

See every plumbing topic

Read, practise, return

  1. 1. Read it in context

  2. 2. Try recalling, then explore practice

    Use the memory prompt below to connect the vocabulary.

  3. 3. Return to the meaning

    After reading or practising, explain the idea in your own words, then check what you remembered.

    Revisit the Indirect cylinder definition

Recall a related term

Which term fits this definition? Say it to yourself, then reveal it. This is a memory prompt, with no score or saved result.

A hot-water cylinder fed from a cold water storage cistern above it, with an open vent pipe that rises over that cistern. Its pressure comes from the height of the cistern, so outlets upstairs can run gently, and it does not carry the layered safety devices an unvented cylinder depends on.

Open a meaning to compare its role with Indirect cylinder, or follow its full entry.

Vented cylinder

A hot-water cylinder fed from a cold water storage cistern above it, with an open vent pipe that rises over that cistern. Its pressure comes from the height of the cistern, so outlets upstairs can run gently, and it does not carry the layered safety devices an unvented cylinder depends on.

Read the Vented cylinder entry
Immersion heater

An electric element that sits inside a hot-water cylinder and heats the water directly, switched by its own thermostat. It is the main heat source in some homes and a backup in others. It runs from an electrical circuit, so a fault on the electrical side is a job for an electrician.

Read the Immersion heater entry

Before you start: some plumbing work is regulated or notifiable

Some water fittings work needs notice to, and consent from, the water supplier before it starts. Check the rules where you live.

Gas work is for competent workers covered by a Gas Safe registered business in Great Britain. Northern Ireland has separate gas regulations. Do not work on gas pipes or appliances yourself.

In England, installing an unvented hot-water system over 15 litres is notifiable building work: use a competent installer registered with a competent-person scheme, or tell building control before work starts. Leave this work to a suitably skilled person.

Wales, Scotland and Northern Ireland have their own water and building rules; check which apply before work starts. Electrical connections belong with an electrician.

This guide does not qualify you or make you competent, approved or registered for plumbing, gas or unvented work.

A definition is a start. Using it in a real question is where it sticks.

By starting, you agree to our Terms and Privacy notice.

Indirect cylinder Meaning in UK Plumbing | TradeTraining