Caravan pitch supply point

The post or unit on a caravan or camping park that gives a pitch its supply, covered by BS 7671's Section 708. Each socket is to BS EN 60309-2, at least IP44 and not less than 16 A, with its own device and its own 30 mA breaking every live conductor. On a supply the pitches are made part of a , because a broken PEN could put a dangerous voltage on a van's metalwork.

Where to look it up: BS 7671 Section 708.

Using Caravan pitch supply point in context

Reviewed

A distinction worth remembering

An RCD's type tells you which kinds of residual current it will reliably respond to. It doesn't tell you how much leakage trips it, which is the mA rating. And it's nothing to do with MCB curves. A Type B RCD and a Type B MCB share a letter and nothing else, because MCB Types B, C and D describe how a breaker responds to overcurrent.

Questions to take further

How can I revise Caravan pitch supply point beyond the definition?
Explain what Caravan pitch supply point describes, compare it with a related term and use it in a topic question. State any assumptions and what evidence you would need before applying the idea to real work.

Sources

Report a mistake

Where Caravan pitch supply point fits in the learning path

The Special Locations section covers these units:

  • Wet locations
  • Sites, farms and shows
  • Moving and temporary
  • Heating, lighting and the outdoors

Curriculum mapping: C&G 2382-26 (BS 7671 Part 7).

See this section in the full curriculum

This section is on the Plus path. Lesson availability depends on content review and your learning path.

Read, practise, return

  1. 1. Read it in context

  2. 2. Try recalling, then explore practice

    Use the memory prompt below to connect the vocabulary.

    Follow a topic above to explore how the term is used, then use the learning entry below to find your path.

  3. 3. Return to the meaning

    After reading or practising, explain the idea in your own words, then check what you remembered.

    Revisit the Caravan pitch supply point definition

Recall a related term

Which term fits this definition? Say it to yourself, then reveal it. This is a memory prompt, with no score or saved result.

An earthing arrangement in which the supply source is earthed and the installation's exposed-conductive-parts connect to an independent earth electrode. The earth path commonly has too much impedance for overcurrent protection alone to meet the required disconnection time, so RCDs are normally used for fault protection. The electrode and protective devices must be assessed together.

Open a meaning to compare its role with Caravan pitch supply point, or follow its full entry.

TT system

An earthing arrangement in which the supply source is earthed and the installation's exposed-conductive-parts connect to an independent earth electrode. The earth path commonly has too much impedance for overcurrent protection alone to meet the required disconnection time, so RCDs are normally used for fault protection. The electrode and protective devices must be assessed together.

Read the TT system entry
RCD — Residual Current Device

A protective device that detects an imbalance between the currents in the live conductors passing through it. In a single-phase circuit this usually means comparing line and neutral current. It disconnects when the residual current meets its operating conditions. A 30 mA RCD can provide additional shock protection, but it does not prevent every kind of electric shock or replace safe isolation.

Read the RCD entry
Open-PEN fault

A break in the PEN conductor of a TN-C-S (PME) supply, out in the distributor's cable. The building's loads then pull its neutral and earth terminal towards the line conductor's voltage, and everything bonded to them follows, while someone outdoors stands on real earth. An RCD won't catch it, which is why BS 7671 sets out specific options for outdoor EV charge points on PME.

Read the Open-PEN fault entry
IP rating — Ingress Protection rating

A code describing specified enclosure protection against access to hazardous parts, solid objects and water. The first characteristic digit concerns access and solid objects; the second concerns water under defined test conditions. An X means that characteristic is not specified. An IP code alone does not establish suitability for heat, corrosion, impact or every outdoor environment.

Read the IP rating entry
Special location

A place or type of installation where the risks are higher or different, so BS 7671's Part 7 adds to or changes its general rules. Bathrooms, swimming pools, construction sites, caravan parks and EV charging all have their own section there. Read that section before designing or testing, because the general parts still apply unless it changes them.

Read the Special location entry

A definition is a start. Using it in a real question is where it sticks.

By starting, you agree to our Terms and Privacy notice.