Notifiable work

Domestic electrical work that must be notified under Part P of the Building Regulations in England and Wales. Wales covers more kinds of work than England; Scotland and Northern Ireland run their own systems. It includes a new circuit, a replacement and some work in bathrooms. There are two lawful routes: an electrician registered with a competent-person scheme certifies and notifies it, or the householder tells local authority building control before starting and pays for it to be inspected.

Where Notifiable work fits in the learning path

The Installation section covers these units:

  • Wiring Systems & Enclosures
  • Cable Selection & Circuit Design
  • Earthing, Bonding & Consumer Units

Curriculum mapping: C&G 2365 Units 203/204/305.

See this section in the full curriculum

This section is on the Plus path. Lesson availability depends on content review and your learning path.

Read, practise, return

  1. 1. Read it in context

  2. 2. Try recalling, then explore practice

    Use the memory prompt below to connect the vocabulary.

  3. 3. Return to the meaning

    After reading or practising, explain the idea in your own words. Revisit the Notifiable work definition to check what you remembered.

Recall a related term

Which term fits this definition? Say it to yourself, then reveal it. This is a memory prompt, with no score or saved result.

The distribution board of a domestic installation. A main switch, residual-current protection and a row of circuit devices on a DIN rail split the incoming supply into individually protected final circuits. Modern UK consumer units sit in non-combustible enclosures and increasingly give every circuit its own RCBO instead of sharing RCDs across banks.

Open a meaning to compare its role with Notifiable work, or follow its full entry.

Consumer unit

The distribution board of a domestic installation. A main switch, residual-current protection and a row of circuit devices on a DIN rail split the incoming supply into individually protected final circuits. Modern UK consumer units sit in non-combustible enclosures and increasingly give every circuit its own RCBO instead of sharing RCDs across banks.

Read the Consumer unit entry
EICR — Electrical Installation Condition Report

The report produced by a periodic inspection of an existing installation, recording its condition against the current edition of BS 7671. Observations are classified by urgency — C1 for danger present, C2 for potentially dangerous, C3 for improvement recommended, and FI where further investigation is needed — and a C1 or C2 makes the report unsatisfactory.

Read the EICR entry