R1+R2
The combined of a circuit's line conductor (R1) and its (R2), measured end-to-end during dead testing. It proves the protective conductor is continuous, and added to it predicts the circuit's before the supply is ever switched on.
How the ideas connect
R1+R2 brings two conductors into one resistance value: R1 is the resistance of the line conductor and R2 is the resistance of the CPC. It connects the idea of a continuous protective conductor with the wider earth fault loop described by Ze and Zs.
Where R1+R2 fits in the learning path
The Testing & Inspection section covers these units:
- Initial Verification & Dead Testing
- Live Testing
- Inspection & Certification
Curriculum mapping: C&G 2365 Unit 304 / 2391.
See this section in the full curriculum
This section is on the Plus path. Lesson availability depends on content review and your learning path.
Read, practise, return
1. Read it in context
- Inspection & TestingTesting & Inspection
- Ring Final CircuitsTesting & Inspection
2. Try recalling, then explore practice
Use the memory prompt below to connect the vocabulary.
- Inspection & Testing — quiz previewPlus · Testing & Inspection
3. Return to the meaning
After reading or practising, explain the idea in your own words. Revisit the R1+R2 definition to check what you remembered.
Recall a related term
Which term fits this definition? Say it to yourself, then reveal it. This is a memory prompt, with no score or saved result.
The earth wire of a circuit. It links the metal parts of the equipment the circuit feeds back to the main earthing terminal. It is not the normal load-current return path, although equipment can produce protective-conductor current in normal operation. During an earth fault it provides a path for fault current, working with the earthing arrangement and protective device to achieve disconnection. In UK wiring it is green and yellow, or bare inside twin-and-earth cable, with green-and-yellow sleeving wherever it is exposed.
Compare related terms
Open a meaning to compare its role with R1+R2, or follow its full entry.
CPC — Circuit Protective Conductor
The earth wire of a circuit. It links the metal parts of the equipment the circuit feeds back to the main earthing terminal. It is not the normal load-current return path, although equipment can produce protective-conductor current in normal operation. During an earth fault it provides a path for fault current, working with the earthing arrangement and protective device to achieve disconnection. In UK wiring it is green and yellow, or bare inside twin-and-earth cable, with green-and-yellow sleeving wherever it is exposed.
Read the CPC entryZs — Earth Fault Loop Impedance
The total opposition to current around the loop a fault current would travel. That loop runs from the supply, along the line conductor to the fault, and back through the protective conductor and the earthing. It is the supply's own part (Ze) plus the circuit's R1 + R2, the resistance of its line and protective conductors. A low Zs lets a big fault current flow, which trips the protective device quickly, so electricians measure it and compare it with the maximum allowed for that device.
Read the Zs entryContinuity testing
Low-resistance measurement proving that conductors which must be complete actually are. That means protective conductors back to the earthing terminal, bonding conductors to services, and the legs of ring final circuits. Performed dead with a low-ohm meter, it is the first step of the test sequence because everything after it assumes the earth path exists.
Read the Continuity testing entryResistance
Resistance describes opposition to current that transfers electrical energy into heat, and is measured in ohms (Ω). For an ohmic component at a fixed temperature, greater resistance means less current at the same voltage. A heating element uses resistance deliberately; cable resistance also causes heating and voltage drop. Resistance is only one part of AC impedance.
Read the Resistance entryImpedance
Impedance is the combined opposition that resistance and reactance present to alternating current, measured in ohms (Ω). Reactance comes from inductance and capacitance, so impedance is not always the same as a resistance reading. Earth fault loop impedance, Zs, describes the whole fault-current path; R1+R2 describes the resistance of two circuit conductors.
Read the Impedance entryA definition is a start. Using it in a real question is where it sticks.